The Eaton 5PX Rack/Tower UPS provides line-interactive backup power and scalable runtimes for servers, storage systems, VoIP gear and network equipment. With a next-generation intuitive LCD display, energy consumption metering down to the outlet group level, and up to 99% efficiency, the 5PX is the perfect UPS to protect modern IT equipment.
| ©2026 Respective owners and brand holders. This table has been carefully researched and generated by ComXpert International CC (//www.comx-computers.co.za), however, errors and omissions may occur. Only references to South Africa apply. All products are sourced in South Africa from the official suppliers and the warranty is that of the local supplier. E&OE. This table and our site's content may be used on condition that this notice and link remains intact and unaltered. |
Specifications |
| Product Code | 5PX3000IRTN |
| General |
| Topology | Line-Interactive High Frequency (Pure Sine wave, Buck + Boost) |
| Configuration | Rack/Tower |
| Catalog Number | 5PX3000iRTN |
| Part Number | 5PX3000iRTN |
| Color | Black |
| Rating (VA/Watts) | 3000/2700 |
| Diagnostics | Full system self-test at power up |
| Efficiency | up to 99% |
| Dimensions (H x W x D, inches) | 3.4 x 17.4 x 25.5 |
| Dimensions (H x W x D, mm) | 86 x 441 x 647 |
| Weight (kg) | 38 |
| Weight (lbs) | 84 |
| Warranty | 3 years on electronics, 3 years on batteries with registration |
| Rail Kit Included | Tower stands and 4-post rail kit included |
| Contents | 5PX3000iRT2UN |
| (Ships with the following items) | Four-post rail kit |
| User manual CD |
| Tower pedestals |
| Network Card-MS |
| Intelligent Power Software Suite CD |
| Quick start guide |
| RS-232 serial cable |
| USB cable |
| 2 IEC to IEC jumper cables |
| Phillips head screw driver |
| Electrical Input |
| Connection | (1) IEC-320-C20 |
| Input Voltage Range | 160–294 Vac (adjustable to 150–294 Vac) |
| Nominal Voltage | 230 Vac (adjustable to 200/208/220/230/240 Vac) |
| Frequency | 50/60 Hz (auto-sensing) |
| Frequency Range | 47–70 Hz (50 Hz system), 56.5–70 Hz (60 Hz system), 40 Hz in low-sensitivity mode |
| Input Power Factor | 0.9 |
| Electrical Output |
| Output Receptacles | (8) IEC-320-C13 |
| (1) IEC-320-C19 |
| On Utility Voltage Regulation | 184–265 Vac |
| On Battery Voltage Regulation | -10%, +6% of nominal |
| Output Frequency | 50/60 Hz ±0.1 % (autosensing) |
| Transfer Time | 1–4 ms typical |
| Load Segments | Group 1: (2) C13 outlets Group 2: (2) C13 outlets |
| Battery |
| Optional Extended Battery Module | 5PXEBM72RT2U |
| Battery Management | ABM technology and temperature-compensated charging method (user selectable), automatic battery test, deep discharge protection, automatic recognition of extended battery modules (EBMs) |
| Battery Type | 12V/9 Ah; sealed, lead-acid; maintenance free |
| Battery Replacement | Hot-swappable internal batteries and extended battery modules (EBMs) |
| Start On Battery | Allows start of UPS without utility power |
| Communications |
| User Interface | LCD graphical display |
| LEDs | Load Protected, Battery, and Fault |
| Communication Ports | 1 USB HID compliant port + 1 RS232 serial port and relay contacts (USB and RS232 ports cannot be used simultaneously) |
| Connectivity Card | Network Card-MS |
| Power Management Software | Eaton Intelligent Power Software Suite CD (included) |
| Environmental & Standards |
| Heat Dissipation (BTU) | Line: 305, Battery: 2047 |
| Audible Noise | <50 dBA |
| Operating Temperature | 0°C–40°C (32°F–104°F) |
| Performance - Safety - EMC | IEC/EN 62040-1-1 (Safety), IEC/EN 62040-2 (EMC), IEC/EN 62040-3 (Performance) |
| Safety markings | CE, CB report, TÜV, C-Tick |
| Storage Temperature | -15°C–50°C (5°F–122°F) |
| Relative Humidity | 20–95% non-condensing |
| Altitude | Up to 10,000 ft (3000m) without de-rating |