Features:
Strong Power
All generator sets are equipped with KIPOR four-stroke engines.
Low Noise Running
High effective combustion system ensures complete combustion, Besides, a large silencer dampens exhaust noise and engine sounds which are contained by a double-wall structure and absorbed by a liner.
Digital Control Panel
All the control units of the generator sets are on one panel, a monitor of the panel will display the real-time working data of the generator set such as its output voltage and current etc. Besides, the running trouble of the generator will also be displayed on the panel.
Low Oil Alarm System
Before the oil level drops to the limited level, the generator set will stop automatically. The whole set can be restarted only if the oil is refilled.
Application of New AVR
The AVR (Automatic Voltage Regulator) not only can smooth the output but also can provide reasonable protection against the overload of the whole set, thus avoid damage to the set.
Advanced Alternator Winding
Waveform distortion is kept at a minimum level and the output is stable. The winding design protects the generator from short circuits and provides a stable output while running inductive loads.
ATS (Automatic Transfer Switch)
On the inheriting of the original general-purpose generator set, KIPOR diesel generator sets with digital control panel can be equipped with a made ATS(automatic transfer switch). ATS, in its preset intervals, can automatically check and monitor the running of the genset to ensure the genset in good working condition. Meanwhile, ATS will monitor the utility power, if utility power fails or the voltage and frequency of the utility power become abnormal, ATS will give commands to start the genset automatically.
Specifications:
| ©2026 Respective owners and brand holders. This table has been carefully researched and generated by ComXpert International CC (//www.comx-computers.co.za), however, errors and omissions may occur. Only references to South Africa apply. All products are sourced in South Africa from the official suppliers and the warranty is that of the local supplier. E&OE. This table and our site's content may be used on condition that this notice and link remains intact and unaltered. |
Specifications |
| Product Code | DNKDE12STA3 |
| Model | KDE12STA3 |
| Rated frequency (Hz) | 50 60 |
| Rated output (kVA) | 10 11.5 |
| Max. output (kVA) | 11 12.65 |
| Rated Voltage (V) | 230/400 240/416 |
| Rated current (A) | 14.5 16 |
| Rated rotation speed (r/min) | 30003600 |
| Phase NO. | Three-phase, Y connection |
| Power factor (Cos Φ) | 0.8(lag) |
| Insulation Grade | B |
| Pole number | 2 |
| Excitation mode | Self-excitation & constant voltage (AVR) |
| Panel Type | Digital Panel |
| Voltage (V) | 230/400 240/416 |
| Receptacle | Two single phase receptacles |
| Connection pole | With |
| DC12V output | Without |
| Overall dimension (L×W×H) (mm) | 1350 X 795 X 850 1350 X 650 X 760 (without wheels) |
| Dry weight(kg) | 310 |
| Working assorting weight (Kg) | 345 |
| Noise level(7m)dB(A) | 72 |
| Structure type | Super Silent |
| Engine Model | KM2V80G |
| Engine Type | Two-cylinder, v-twin, water-cooled, four-stroke, swirl chamber |
| Cylinder NO.-bore×stroke (mm) | 2-80×79 |
| Displacement (ml) | 794 |
| Rated power [KW/(r/min)] | 12.5/3000 14.5/3600 |
| Compression ratio | 23:1 |
| Rated rotation speed (r/min) | 30003600 |
| Combustion system | — |
| Cooling system | Water cooled |
| Lubrication system | Pressure splashed |
| Starting system | Electric starter |
| Fuel type | 0# (summer)- 10# (winter)- 35#(chillness)diesel |
| Lube oil brand | CD grade or SAE10W-30,15W-40 |
| Capacity of cooling water (L) | 3.5 |
| Lube capacity (L) | 2.27 |
| Starting motor capacity (V-kW) | 12V 1.4kW |
| Charging generator capacity (V-A) | 12V 20A |
| Battery capacity (V-Ah) | 12V 36Ah |
| Fuel consumption (g/kW.h) | ≤340 |
| Fuel tank capacity (L) | 26 |
| Continuous running time (hr) | 7 |