| ©2026 Respective owners and brand holders. This table has been carefully researched and generated by ComXpert International CC (//www.comx-computers.co.za), however, errors and omissions may occur. Only references to South Africa apply. All products are sourced in South Africa from the official suppliers and the warranty is that of the local supplier. E&OE. This table and our site's content may be used on condition that this notice and link remains intact and unaltered. |
Specifications |
| Product Code | SMX700HG |
| OVERVIEW |
| UPC Code | 37332140418 |
| UPS Type | Line-Interactive |
| INPUT |
| Input Phase | Single-Phase |
| Rated input current (Maximum Load) | 3.6A |
| Nominal Input Voltage(s) Supported | 230V AC |
| UPS Input Connection Type | C14 inlet |
| UPS Input Cord Length (ft.) | 0.5 |
| UPS Input Cord Length (m) | 0.2 |
| Recommended Electrical Service | 10A 230V |
| Voltage Compatibility (VAC) | 230 |
| OUTPUT |
| Output Capacity (VA) | 700 |
| Output Capacity (kVA) | 0.7 |
| Output Capacity (Watts) | 450 |
| Output Capacity (kW) | 0.45 |
| Nominal Voltage Details | 230v nominal inverter output voltage |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Automatic frequency selection |
| Output Voltage Regulation (Line Mode) | -18%, +8% |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Nominal Output Voltage(s) Supported | 220V; 230V; 240V |
| Output Receptacles | (6) C13 |
| BATTERY |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Runtime Full Load (min.) | 14.5 min. (450W) |
| Runtime Half Load (min.) | 36 min. (225W) |
| DC System Voltage (VDC) | 36 |
| Battery Recharge Rate (Included Batteries) | Less than 3.6 hours from 10% to 90% (typical, full load discharge) |
| Battery Access | Battery access door allows hot swap battery replacement without powering connected equipment off |
| Internal UPS Replacement Battery Cartridge | RBC36SLT |
| Typical Battery Lifespan | 3-6 years, depending on usage |
| VOLTAGE REGULATION |
| Voltage Regulation Description | Line interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 155 to 274V AC |
| Overvoltage Correction | Input voltages between 206 and 245V AC are reduced by 9% |
| Undervoltage Correction | Input voltages between 183 and 199 are boosted by 10% |
| Severe Undervoltage Correction | Input voltages between 155 and 182 are boosted by 21% |
| USER INTERFACE, ALERTS & CONTROLS |
| Switches | Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions |
| Audible Alarm | 3 function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone). Audible Alarm is factory muted for silent operation; Audible alarm can be restored to indicate power failure, overload conditions and Low Battery events, using our Free PowerAlert UPS management software. |
| LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
| SURGE / NOISE SUPPRESSION |
| UPS AC Suppression Joule Rating | 340 |
| EMI / RFI AC Noise Suppression | Yes |
| AC Suppression Response Time | Instantaneous |
| PHYSICAL |
| Primary Form Factor | Tower |
| Cooling Method | Cooling via rear-exit cooling fan |
| Installation Form Factors Supported with Included Accessories | Tower |
| Installation Form Factors Supported with Optional Accessories | Wallmount ( - tower mounting kit) |
| Primary UPS Depth (mm) | 229 |
| Primary UPS Height (mm) | 325 |
| Primary UPS Width (mm) | 191 |
| Shipping Dimensions (hwd / cm) | 46.99 x 30.99 x 33.99 |
| Shipping Weight (kg) | 20.59 |
| UPS Housing Material | PVC |
| UPS Power Module Dimensions (hwd, cm) | 32.51 x 19.05 x 22.86 |
| UPS Power Module Weight (kg) | 19.1 |
| Unit Weight (kg) | 19.1 |
| ENVIRONMENTAL |
| Operating Temperature Range | 32° to 104°F (0° to 40°C) |
| Storage Temperature Range | 5° to 122°F (-15° to 50°C) |
| Relative Humidity | 0 to 95%, non-condensing |
| AC Mode BTU / Hr. (Full Load) | 208.6 |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 189.1 |
| COMMUNICATIONS |
| Network Management Card Description | Network management not supported |
| Communications Interface | USB; DB9 Serial |
| LINE / BATTERY TRANSFER |
| Transfer Time | 5 milliseconds |
| Low Voltage Transfer to Battery Power (Setpoint) | 155 |
| High Voltage Transfer to Battery Power (Setpoint) | 274 |
| FEATURES & SPECIFICATIONS |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| High Availability UPS Features | Surge/noise protection |
| Grounding Details | Equipotential connection (back panel grounding lug) |
| APPLICATIONS |
| UPS Applications | Hospital/Medical |
| STANDARDS & COMPLIANCE |
| Product Certifications | UL 60601-1 |
| Product Compliance | RoHS; CE (Europe) |